Mineral insulating oils - Determination of kinematic viscosity at very low temperatures (IEC 61868:1998); German version EN 61868:1999

More details

This product is no longer in stock

$38.31

More info

The document specifies a procedure for the determination of the kinematic viscosity of mineral insulating oils, both transparent and opaque, at very low temperatures, after a cold soaking period of at least 20 h, by measuring the time for a volume of liquid to flow under gravity through a calibrated glass capillary viscometer. It is applicable at al temperatures to both Newtonian and non-Newtonian liquids having viscosities of up to 20000 mm2 × s-1. It is particularly suitable for the measurement of the kinematic viscosity of liquids for use in cold climates, at very low temperatures (- 40 °C) or at temperatures between the cloud and pour-point temperatures (typically - 20 °C) where some liquids may develop unexpectedly high viscosities under cold soak conditions.

Author VDE
Editor VDE
Document type Standard
Format Paper
ICS 29.040.10 : Insulating oils
Number of pages 10
Replace DIN IEC 10/415/CDV (1997-10)
Cross references EN 61868 (1999-01), IDT
Weight(kg.) 0.1170
Year 1990
Document history DIN EN 61868 (1999-12)
Country Germany
Keyword EN 61868;61868