Sale! View larger

AWWA ACE58128

New product

AWWA ACE58128 Bench- and Full-Scale Testing to Develop PAC Dose-Response Curves for Removal of Geosmin and MIB at the North Texas Municipal Water District

Conference Proceeding by American Water Works Association, 06/15/2003

Bond, Rick; Timmerman, David; Long, Steve; McKnight, Dolan

More details

$12.00

-50%

$24.00

More info

Full Description

The North Texas Municipal District (NTMWD) experiences seasonal taste and odor(Tto compare the treatment efficiencies for PAC addition at the raw water intake andrapid mix basin; and,to evaluate the cost efficiency of different PAC types.Several researchers have demonstrated that geosmin is more readily removed by PACadsorption than MIB 2, 3, 4. Consequently, MIB was selected for testing to provide aconservative representation of treatment requirements for geosmin removal. The jartesting protocol was designed to simulate contact time and chemical additions at the fullscaleplants.Following jar testing, full-scale tests were conducted at one of the NTMWD watertreatment plants. The objectives of the full-scale tests were: to verify bench-scale testresults and calibrate the bench-scale dose-response curves to full-scale conditions; and, totest the effects of sufficient PAC doses on filter headloss. PAC addition was tested at therapid mix basin and with 30 minutes of PCT to simulate addition at the raw water intake.During full-scale testing, filter headloss was measured every two hours to evaluate theimpact of the PAC doses on filter run times. Includes 5 references, tables, figures.

Product Details

Edition: Vol. - No. Published: 06/15/2003 Number of Pages: 13File Size: 1 file , 290 KB