Sale! View larger

AWWA ACE56214

New product

AWWA ACE56214 Critical Aspects of UV Dose Delivery Monitoring

Conference Proceeding by American Water Works Association, 06/16/2002

Wright, Harold; Cushing, Robert

More details

$12.00

-50%

$24.00

More info

Full Description

This paper provides a description of the dose monitoring approaches used by ultraviolet (UV) reactors designed to treat drinking water and addresses issues including: comparing the different monitoring methods; the optimum position for UV intensity sensors relative to the UV lamps; the impact of differing UV intensity sensor properties; and, safety factors required to account for uncertainty in dose monitoring. Approaches used by UV reactors to monitor dose delivery fall into three categories: UV intensity setpoint approaches; UV intensity / UV transmittance setpoint approaches; and, calculated dose approaches. Includes 8 references, tables, figures.

Product Details

Edition: Vol. - No. Published: 06/16/2002 Number of Pages: 17File Size: 1 file , 460 KB